Rate
Schedules and Policies
RSP
N-18
Rate
Schedules and Rate Application Guidelines
Unmetered
Rate Application Guidelines
Services
for which electricity consumption is uniform and easily estimated.
Services where metering is not considered practical by Maritime
Electric.
Specific applications of the Unmetered Rates include:
-
-
Self
- contained sign lighting;
-
Architectural
flood lighting;
-
-
-
-
-
-
-
Highway
traffic counters; and
-
Estimating
Consumption
Electricity consumption is estimated by multiplying the connected
load in watts times the hours of usage. For example, a photoelectrically
controlled 100 watt sign light operates approximately 12 hours
per day, has an estimated annual consumption calculated as follows:
100 watts x 12 hours x 365 days = 438,000 watt-hours or 438
kWh per year.
If conditions are such as to cause reasonable doubt concerning
the connected load, recording equipment will be installed to
determine the kW connected load.
Energy Cost Adjustment Mechanism: This rate is subject to the Energy Cost Adjustment Mechanism
RSP
N-19
Rate
Schedules and Rate Application Guidelines
Miscellaneous
Rate Schedules
Air Raid and Fire
Sirens (unmetered)
Customer is charged $4.17 per month per HP of nameplate rating.
(Code 840)
Outdoor Christmas Lighting
Customer is charged 4.28¢ per watt of connected load per
week. The minimum charge is for a period of one (1) week.(Code
850)
Energy Cost Adjustment Mechanism: This rate is subject to the Energy Cost Adjustment Mechanism
RSP
N-20
Rate
Schedules and Rate Application Guidelines
Short
Term Unmetered Rate Schedule
That category
of customers in all areas served by Maritime Electric requiring
single-phase and three-phase installations and connected for
no longer than one (1) month. The installation will not be metered.
Rate
Connection Charge: |
Single-Phase
|
Three-Phase
|
| A.
Connecting to existing Secondary voltage |
$91.40
|
$91.40
|
| B.
Where transformer installations are required, the following
connection charges will apply: |
Single-Phase
|
Three-Phase
|
| (1)
Up to and including 10 kVA |
$137.33
|
$192.96
|
| (2)
11 kVA to 15 kVA |
$222.13
|
$277.68
|
| (3)
16 kVA to 25 kVA |
$248.34
|
$310.55
|
| (4)
26 kVA to 37 kVA |
$277.68
|
$310.55
|
| (5)
38 kVA to 50 kVA |
$310.55
|
$310.55
|
| (6)
51 kVA to 75 kVA |
$340.94
|
$483.36
|
| (7)
76 kVA to 125 kVA |
$397.67
|
$512.54
|
| (8)
Above 125 kVA |
-
|
$548.84
|
Energy Charge:
13.58¢ per kWh of estimated consumption
Energy Cost Adjustment Mechanism: This rate is subject to the Energy Cost Adjustment Mechanism
RSP
N-21
Rate
Schedules and Rate Application Guidelines
Short
Term Unmetered Rate Application Guidelines
Available to serve such events as carnivals, bazaars and unmetered
installations.
Connected for no longer than one (1) month.
When the service exceeds one month, the installation will be
billed and the remaining time considered as a new installation.
When meters are involved, and not disconnected, a reading will
be taken and the kilowatt hours noted for record purposes only.
When poles or additional equipment other than the transformer
installation are required, the installation and removal charges
will be estimated and collected before work commences. Customers
who have a credit history, acceptable to Maritime Electric,
may be billed using a Customers Contribution Estimate.
Estimating Consumption
Electricity consumption is estimated by multiplying the connected
load in kW (or kVA times 0.9), times the hours of usage. For
example, a carnival with a connected load of 25 kVA operates
12 hours per day for 10 days has an estimated consumption calculated
as follows:
25 kVA x 0.9 power factor x 12 hours x 10 days = 2,700 kWh.
If conditions are such as to cause reasonable doubt concerning
the connected load, recording equipment will be installed to
determine the kVA connected load.
Energy Cost Adjustment Mechanism: This rate is subject to the Energy Cost Adjustment Mechanism
|
|